SWCMC Series Densely Insulated BuswayThe SWCMC Series Densely Insulated Busway is suitable for AC three - phase four - wire and three - phase five - wire systems with a frequency of 50~60Hz and a rated current of 100~5000A in power supply and distribution systems. It is used for outputting electrical energy in the power supply and distribution systems of industrial and mining enterprises, public institutions, and high - rise buildings. It is especially suitable for workshops and the renovation of old enterprises. | |
|
Product Description Specification 1. Scope of application SWCMC series densely insulated bus ducts are suitable for AC three-phase four-wire and three-phase five-wire systems with a frequency of 50-60Hz and a rated current of 100-5000A. They are used to output power for power supply and distribution systems in factories, mines, enterprises, institutions and high-rise buildings, and are particularly suitable for the renovation of workshops and old enterprises. 2. Structural characteristics Strong heat dissipation capacity This series of busbars features close contact between phases and between phases and the housing, allowing them to withstand significant electrodynamic and thermal stresses. They also rapidly dissipate heat generated by the conductive bars, resulting in high current carrying capacity. Joints are secured with insulated bolts and connected using double copper busbars, effectively increasing the joint contact area and significantly reducing temperature rise. Flexible wiring This series of bus ducts has flexible and convenient interface settings, can be set up with a large number of sockets, and has strong versatility. When adjusting the position of electrical equipment, there is no need to change the power supply system. three,Structural characteristics The bus duct complies with IEC439-2 and GB7251.2-1997. The bus duct can ensure long-term normal operation at rated current and 110% rated voltage. The bus duct has passed the dynamic and thermal stability tests according to the data in Table (1), and after the test, the bus duct has no perceptible permanent deformation. SWCMC-2A series bus duct can withstand 3750V.T frequency withstand voltage and last for 1 minute without breakdown or flashover. When the rated current is passed through it for a long time, the temperature rise of its conductive parts shall not exceed the values listed in Table (2). Main technical parameters
The plug-in and unplugging times of the junction box and the bus duct shall not be less than 200 times. The SWCMC series bus duct has a fully enclosed structure and a protection level of up to IP40. The cross-sectional dimensions and weight per meter of bus duct are shown in Figure (1) and Table (3).
Main technical parameters
Connection Installation SWCMC bus duct is equipped with high insulation and high mechanical strength insulation board as connection accessories. The connection method of the joint is shown in Figure (2).
The comparison of bus duct rated current and busbar specifications per phase is shown in Table (4)
|
|
|