Nanning University Training Building Power Distribution Project
Nanning University is an undergraduate institution under the jurisdiction of the Guangxi Zhuang Autonomous Region. The power distribution system of the teaching buildings needs to meet the following requirements:
− Load diversity: Mixed loads such as laboratory equipment, multimedia classrooms, lighting, and air - conditioners;
− Safety specifications: Places with a dense population of teachers and students need to comply withthe GB7251.1 standard for electric shock protection;
− Space limitation: The power distribution room needs to make efficient use of the limited area;
− Expansion requirements: Support the capacity increase of subsequent teaching equipment.
Applied products
Schneider authorized box Prisma E standardized low - voltage complete distribution equipment
Siwu Solution
Customer Value
1. Modular and flexible expansion
− 25mm standard modular design: Supports free combination of functional units according to teaching needs;
− Component - based upgrade:The IP40 protection scheme can be directly expanded to the IP54 scheme.
2. Safety - enhanced design
− Patented door lock structure: Instantly releases short - circuit pressure to prevent the cabinet door from bursting open;
− Full insulation protection: The surface of the terminal distribution box has zero potential, complying withGB7251.1 safety standard.
Expand flexibility
− The modular structure supports rapid circuit expansion during subsequent capacity increase of teaching equipment.
Safety and compliance guarantee
− PassedVerification of electric shock protection in GB7251.1 - 2013.
Ensuring the continuity of teaching
− Live maintenance of single - circuit reduces the impact of power outages on teaching.
3. Space depth optimization
− Compact cabinet: minimum depth235mm, suitable for narrow distribution rooms;
− Wall-mounted installation: reduces aisle occupation.
4. Convenience of operation and maintenance
− Inspection of independent functional units: no need to power off the whole area for single - area maintenance;
− Large - angle operation of the front door: no obstacles for tool operation.
1. Limited expansion of traditional power distribution cabinets
− When adding new loads, overall renovation is required, and circuits cannot be supplemented as needed.
2. Insufficient safety protection
− There is a risk of exposed live parts in public areas such as classrooms.
4. Operation and maintenance affects the teaching order
− Maintenance requires power outage, which interferes with normal teaching activities.
3. Low space utilization
− The standard cabinet depth is usually>600mm, which squeezes the space of the switchgear room.
|
|