Star ProductsMedium and High Voltage SwitchgearLow Voltage SwitchgearSubstationsPower Distribution BoxesAuthorized CabinetsPhotovoltaic CabinetsGas-Insulated CabinetsBuswaysComprehensive Training Building (EPC) ProjectEPC Engineering of Du'an People HospitalEPC Project of Teng County Industrial Park40.008MWp Distributed Photovoltaic ProjectPower Engineering General ContractingBYD's Phase III Power Distribution ProjectNanning Qingxiu Tesla Center Power DistributionGaoshan Operation Area Power Distribution ProjectGuida Paper 35kV Substation EngineeringIron & Steel Base Power Distribution Project10kV Power Distribution Project for Cold StorageIndustryBeitou Yinshan Power Distribution ProjectPower Distribution Project of Hezhou Binfen MallLiuzhou CR Land Power Distribution ProjectGuangxi MYJ Industry Power Distribution ProjectPower Distribution Project of Creative ParkCommercial Real EstateIndustry - Education Integration Power SupplyYao Medicine Hospital Power Distribution ProjectMuseum Power Distribution ProjectSurveying & Mapping Bureau. Power Distribution ProIntegration Training Building Power DistributionGX Agricultural Vocational and Technical UniversitNanning University Training Building Power DistribGX Agricultural Engineering Vocational and TechnicPujin Road Phase II Sewage Pipe Box-type SubstatioInfrastructureBaise Sports Center Charging Piles Power DistributNapo People's Court Charging Piles Power DistributSmart Park Charging Piles Power Distribution ProjeEnergy and PowerPower Distribution Project of Nanning Rail TransitTian'e-Beihai Highway Power Distribution ProjectGuanyang - Pingle Mechanical & Electrical EngineerTransportation1.92MW Distributed Photovoltaic Power ProjectPhotovoltaic Power Generation Project (Phase I)Agriculture, Forestry, Animal Husbandry & FisheryProjects OverviewNews CenterVideo UpdatesIndustry FAQIndustry White PaperGroup ProfileIndustrial Products Platform QiansimaiHonors and QualificationsSeeking Overseas Distributors
Share to:

GZDW Intelligent High - frequency DC Control Panel

The GZDW series DC panels use cadmium - nickel batteries and floating chargers, and are equipped with automatic detection and alarm devices. They have the characteristics of long service life, no pollution, convenient maintenance, stable voltage, ultra - low internal resistance output, ability to withstand large - current impacts, strong adaptability, and high reliability. They are an ideal DC operating power supply device and can be widely used in substations and power plants below 500KV. They can also be applied in sectors such as metallurgy, mines, petroleum, radio and television, computer rooms, subways, and high - rise buildings as DC control, signal power supplies, power for power - off protection, and power for the opening and closing of circuit breaker operating mechanisms. This product complies with the JB/T5777.4 - 2000 "General Technical Conditions and Safety Requirements for DC Power Supply Equipment in Power Systems" standard.
Product Description
Specification

one,Product Overview

The GZDW series DC panel uses nickel-cadmium batteries, a float charger, and is equipped with an automatic detection and alarm device. It features long service life, zero pollution, easy maintenance, stable voltage, ultra-low internal resistance output, high current surge resistance, strong adaptability, and high reliability. It is an ideal DC operating power supply unit and can be widely used in substations and power plants of 500kV and below. It can also be used in metallurgy, mining, petroleum, radio and television, computer rooms, subways, high-rise buildings, and other sectors as a DC control, signal power supply, power-off protection, and the power supply for opening and closing circuit breaker operating mechanisms. This product complies with the JB/T5777.4-2000 standard, "General Technical Conditions and Safety Requirements for DC Power Supply Equipment in Power Systems."

2. Normal use conditions

Ambient temperature:-50℃~+40℃, and the average temperature within 24 hours does not exceed +36℃.

Altitude:Not exceeding 2500m.

relative humidity: Not exceeding 50% when the ambient air temperature is +40℃.

Higher relative humidity is possible at lower temperatures(For example, 90% at +20°C). Considering the temperature change, moderate condensation is allowed. The equipment should be installed at an inclination of no more than 5° from the vertical. The equipment should be installed in a place free from severe vibration, impact, and corrosion.

3. Ordering Instructions(Please specify when ordering)

1. Main circuit scheme number, purpose, single-line system diagram, arrangement diagram and distribution room layout diagram, etc.

2. Auxiliary circuit wiring schematic and terminal arrangement diagram.

3. Model, specification and quantity of electrical components in the switchgear.

4. Requirements for control, measurement and protection functions of switchgear and requirements for other locking and automatic devices.

5. If a busbar bridge is required between switchgear or incoming cabinets, the specific requirements such as the rated current carrying capacity of the busbar bridge, the span of the busbar bridge, and the height from the ground should be provided.

6. When accessories or spare parts are required, the type and quantity should be specified.

7. If the switchgear is used in special environmental conditions, other special requirements should be specified in detail when ordering.

Four,Features

The dual-channel AC input controlled by microcomputer can be automatically converted.

The AC input over-voltage, under-voltage, over-current, phase loss and zero loss are automatically detected, displayed and alarmed. The charging and floating charging devices use intelligent high-frequency switching rectifier modules.N+1 redundancy is combined, current is automatically balanced, and hot plugging and unplugging are possible. The battery equalization and float charging processes are automatically switched and can operate normally according to the computer settings. Grid decoupling, power restoration and other procedures realize intelligent equalization and float charging management of batteries. When the microcomputer control device fails or issues an erroneous control command, the charging module enters an autonomous working state and the output voltage is the factory-set safety voltage to ensure the reliability of system operation. The intelligent four-remote control system provides detailed communication protocols for AC input, DC output, battery circuit and expanded environmental monitoring, and has an intelligent interface for communication with the substation integrated automation system.。



技术参数


输入电压                 AC380V

控制

母线

最大经常性
负荷电流

300A

合闸母线

合闸脉冲电流

5000A


输出电压         DC220/110/48/24V

事故负荷电流

<300A

合闸脉冲时间

0.3h


事故负荷时间

8b


电池容量(最大)           3000AH

馈出路数

4-6Track路

馈出路数

4-6Track路