KYN28-12 (GZS1) Armored Withdrawable AC Metal-Enclosed SwitchgearIt is applicable to three-phase AC 50Hz power systems for receiving and distributing electrical energy, as well as controlling, protecting, and monitoring circuits. The newly introduced and developed high-current, high-breaking switchgear can also be used independently as the outlet of a high-voltage generator. This product complies with the standards: GB3906 "3~35kV AC Metal-Enclosed Switchgear", GB/T11022 "Common Technical Requirements for High-Voltage Switchgear and Controlgear Standards", and IEC298 "AC Metal-Enclosed Switchgear and Controlgear Rated Above 1kV and Up to and Including 52kV". | |
|
Product Description Specification The KYN28 - 12(GZS1) type armored removable AC metal - enclosed switchgear (hereinafter referred to as "switchgear") is applicable to the three - phase AC 50Hz power system. 3Used for receiving and distributing electric energy and controlling, protecting and monitoring the circuit. The newly introduced and developed high - current, high - breaking switchgear can also be used alone at the outlet of high - voltage generators. This product complies with the standards: GB3906 "3~35kV AC Metal - Enclosed Switchgear", GB/T11022 "Common Technical Requirements for High - Voltage Switchgear and Controlgear Standards", IEC298 "AC Metal - Enclosed Switchgear and Controlgear Rated for Voltages above 1kV and up to and including 52kV". 1. Environmental conditions for use Ambient air temperature: Maximum temperature +40℃, minimum temperature - 15℃. Humidity conditions: Daily average relative humidity: ≤95%, daily average water vapor pressure does not exceed 2.2kPa; Monthly average relative humidity: ≤90%, monthly average water vapor pressure does not exceed 1.8kPa. Altitude: 2500m and below. Seismic intensity: No more than 8 degrees. The ambient air should not be significantly polluted by corrosive or combustible gases, water vapor, etc. Places without frequent and severe vibrations. If used under conditions exceeding the normal conditions specified in GB3906, the user and the manufacturer shall negotiate. 2. Structural features Structure of the switchgear (see the figure below) All - metal assembly, modular assembly structure. The cabinet is made of imported aluminum - zinc coated thin steel plates, processed by the FMS flexible processing system, using the advanced multiple folding process, connected with pull - rivet nuts and high - strength bolts, featuring high precision, corrosion resistance, light weight, high strength and strong versatility. It can be equipped with the ZN63A - 12(VS1) series or the imported IVD4 series vacuum circuit breakers produced, with wide applicability, high reliability and maintenance - free. The trolley is provided with working and test positions, and each position has a positioning and display device, which is safe and reliable. Trolleys of the same specification can be freely interchanged, with strong interchangeability. The trolley is transported by a special carrier vehicle, with easy and flexible operation. Up to 9 single - core cables can be installed in the cable chamber. Reliable mechanical and electrical interlocking devices fully meet the requirements of "Five - Prevention". All high - voltage chambers are equipped with pressure - relief channels to ensure personal safety. The front door is equipped with an observation window to observe the working status of the components inside the chamber. 3. Product picture display
Main technical parameters
Note: 1. The short - circuit capacity of the current transformer shall be considered separately. 2. For the technical parameters of ZN63A - 12, please refer to the corresponding sample. 3. For the type with an altitude of 1000m, the rated current<1250A and the rated breaking current ≤31.5kA. |
|
|