KYN61-40.5 Armored Withdrawable AC Metal-Enclosed SwitchgearThe KYN61-40.5 armored withdrawable AC metal-enclosed switchgear (hereinafter referred to as “switchgear”) is mainly characterized by being equipped with ZN85-40.5, VD4, and VB2 type fully insulated vacuum circuit breakers and spring operating mechanisms inside the cabinet. The cabinet is assembled with aluminum-zinc coated plates, which improves the matching accuracy between the trolley and the cabinet. The trolley can be easily pushed in and pulled out, and it has strong interchangeability. It has an attractive appearance, complete schemes, and is safe and reliable to use. This product is used in the 35KV three-phase AC 50Hz power system for receiving and distributing electric energy in the power distribution rooms of power plants, substations, and industrial and mining enterprises. It has functions such as control, protection, and monitoring. This product complies with the standards of GB3906 “3~35kV AC Metal-Enclosed Switchgear”, GB/T11022 “Common Technical Requiremen | |
|
Product Description Specification 1. Product Overview
The KYN61-40.5 armored removable AC metal-enclosed switchgear (hereinafter referred to as "switchgear") features ZN85-40.5, VD4, and VB2 fully insulated vacuum circuit breakers and a spring-operated mechanism. The cabinet is constructed of aluminum-zinc plate, improving the precision of the trolley-to-cabinet fit. The trolley is easy to push and pull, offering strong interchangeability. The switchgear offers an attractive appearance, a comprehensive range of solutions, and is safe and reliable to use. This product is used forIn 35KV three-phase AC 50Hz power systems, it is used as a distribution room in power plants, substations and industrial and mining enterprises to receive and distribute electric energy, and has control, protection and monitoring functions. This product complies with: GB3906 "3~35kV AC metal-enclosed switchgear", GB/T11022 "Common technical requirements for high-voltage switchgear and controlgear standards", DL/T404 "Technical conditions for ordering AC high-voltage switchgear", IEC298 "AC metal-enclosed switchgear and controlgear with rated voltage above 1kV and 52kV and below" standards.
2. Normal use conditions Ambient air temperature:-15℃~+40℃ Altitude:2500m and below. Humidity conditions: The daily average value shall not exceed 95%, and the daily average value of water vapor pressure shall not exceed 2.2kPa; the monthly average value shall not exceed 90%, and the monthly average value of water vapor pressure shall not exceed 1.8kPa. earthquake intensity:No more than 8 degrees. Places without obvious pollution such as corrosive or flammable gases. Note: If the above normal use conditions are exceeded, the user may negotiate with the company。
3. Ordering Instructions(Please specify when ordering) 1. Main circuit scheme number, purpose, single-line system diagram, arrangement diagram and distribution room layout diagram, etc. 2. Auxiliary circuit wiring schematic and terminal arrangement diagram. 3. Model, specification and quantity of electrical components in the switchgear. 4. Requirements for control, measurement and protection functions of switchgear and requirements for other locking and automatic devices. 5. If a busbar bridge is required between switchgear or incoming line cabinets, specific requirements such as the rated current carrying capacity of the busbar bridge, the span of the busbar bridge, and the height from the ground should be provided. 6. When accessories or spare parts are required, the type and quantity should be specified. 7. If the switchgear is used in special environmental conditions, please specify in detail when ordering.
4. Structural characteristics This product consists of two parts: the cabinet and the trolley. The cabinet is made of bent steel plates, sprayed with plastic and assembled with bolts. According to the functional characteristics, it can be divided into four parts: small busbar room, relay instrument room, trolley room, cable room and busbar room. Each part is separated by a grounded metal partition. The cabinet shell protection level isIP4X; with the trolley compartment door open, the protection level is IP2X. This switchgear features main circuit solutions including cable inlets and outlets, overhead inlets and outlets, busbar interconnection, isolation, voltage transformers, and lightning arresters. The busbars utilize composite insulation, with phases and connectors fitted with flame-retardant injection-molded insulating sleeves. Busbar bushings separate adjacent main busbar cabinets, effectively preventing the spread of accidents and providing auxiliary support for the main busbars. The cable compartment is equipped with an earthing switch and overvoltage protection devices. There is a metal valve in front of the contact box. The upper and lower valves are disconnected when the trolley is turned on./ It opens automatically when the test position moves to the working position, and closes automatically when the trolley moves in the opposite direction. It is effective with high pressure Isolation. The interlocking between the main switch, trolley, grounding switch and cabinet door adopts mandatory mechanical locking mode to meet"Five-protection" functional requirements. The circuit breaker trolley adopts a screw drive propulsion mechanism and an overrunning clutch. The screw nut propulsion mechanism can be easily operated to move the trolley between the test position and the working position. With the help of the self-locking property of the screw nut, the trolley can be reliably locked in the working position to prevent accidents caused by the movement of the trolley due to the action of electric power. The overrunning clutch works when the trolley moves back to the test position and when it reaches the working position, so that the operating shaft and the screw shaft are automatically disengaged and idle, which can prevent damage to the propulsion mechanism due to misoperation. Other trolleys use a lever propulsion mechanism. The test working position has a positioning pin lock. The cabinet dimensions are: width x depth x height (mm): 1400x2800 (3000) x2600。
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|