SWDFW-12 Outdoor Switchgear (Cable Distribution Box)A switchgear is used to take a single power supply from a sub - station and distribute the electricity to several areas or different buildings in need of power through multiple switch cabinets installed in the “switchgear”. The voltage remains unchanged. Figuratively speaking, it “divides” a single power supply into multiple power supplies. It uses pre - fabricated live - touchable silicone rubber cable heads, which are fully sealed, fully insulated and maintenance - free, reliably ensuring personal safety. It has a compact structure, a small and beautiful appearance, and a stainless - steel double - layer box, with a service life of more than twenty years. | |
|
Product Description Specification 1. Features It uses prefabricated live touchable silicone rubber cable heads, which are fully sealed, fully insulated, and maintenance-free, which can reliably ensure personal safety. It has a compact structure, a small and beautiful appearance, and a stainless steel double-layer box with a service life of more than 20 years. Without affecting the operation of the main grid, regional power outages and maintenance can be carried out to reduce the scope of the outage. It can be equipped with one or more SF6 load switches. The wiring methods are flexible and diverse, and the branch line can reach up to 8 circuits. Optional lightning arresters, short-circuit fault indicators, current-limiting fuses, etc. can meet various user requirements.
2. Scope of Application It is widely used in urban power grid transformation, residential areas, commercial centers and other densely populated areas. 3. Usage conditions and environment The altitude does not exceed 2500m. Ambient temperature: -45℃-+45℃. Relative humidity: daily average value not exceeding 95%, monthly average value not exceeding 90%. Installation location: A location without fire, explosion hazards, conductive dust, chemical corrosive gases and severe vibrations. If the above conditions are exceeded, the user can negotiate with our company. 4. Commonly used cable connectors Made of imported high-quality insulating rubber through fully automated injection molding, the inner and outer layers are both semiconducting shields. The inner layer balances the internal electric field, while the outer shield is grounded to maintain zero potential on the cable head surface. The inner layer at the lower end of the stress cone is in close contact with the cable's semiconducting layer, while the outer semiconducting layer is in close contact with the outer semiconducting layer of the cable head and is grounded through the cable head's grounding hole. This not only eliminates the problem of electric field concentration at the cutoff point of the cable's outer shield, but also maintains zero potential on the cable's outer shield, ensuring personal safety. The front connector of the touchable cable is directly installed on the equipment casing, and can then be connected to the rear connector of the touchable cable to form multiple outgoing lines. It can also be connected to the lightning arrester to provide overvoltage protection for the power grid. Made of imported high-quality insulating rubber through fully automated injection molding, the inner and outer layers are both semiconducting shields. The inner layer balances the internal electric field, while the outer shield is grounded to maintain zero potential on the cable head surface. The inner layer at the lower end of the stress cone is in close contact with the cable's semiconducting layer, while the outer semiconducting layer is in close contact with the outer semiconducting layer of the cable head and is grounded through the cable head's grounding hole. This not only eliminates the problem of electric field concentration at the cutoff point of the cable's outer shield, but also maintains zero potential on the cable's outer shield, ensuring personal safety. The touchable cable rear connector is installed on the touchable cable front connector through a connector. Its rear end can be connected to another rear connector through a connector to form multiple outgoing lines. It can also be connected to a voltage avoider to provide overvoltage protection for the power grid. Technical Parameters
|
|
|