Star ProductsMedium and High Voltage SwitchgearLow Voltage SwitchgearSubstationsPower Distribution BoxesAuthorized CabinetsPhotovoltaic CabinetsGas-Insulated CabinetsBuswaysComprehensive Training Building (EPC) ProjectEPC Engineering of Du'an People HospitalEPC Project of Teng County Industrial Park40.008MWp Distributed Photovoltaic ProjectPower Engineering General ContractingBYD's Phase III Power Distribution ProjectNanning Qingxiu Tesla Center Power DistributionGaoshan Operation Area Power Distribution ProjectGuida Paper 35kV Substation EngineeringIron & Steel Base Power Distribution Project10kV Power Distribution Project for Cold StorageIndustryBeitou Yinshan Power Distribution ProjectPower Distribution Project of Hezhou Binfen MallLiuzhou CR Land Power Distribution ProjectGuangxi MYJ Industry Power Distribution ProjectPower Distribution Project of Creative ParkCommercial Real EstateIndustry - Education Integration Power SupplyYao Medicine Hospital Power Distribution ProjectMuseum Power Distribution ProjectSurveying & Mapping Bureau. Power Distribution ProIntegration Training Building Power DistributionGX Agricultural Vocational and Technical UniversitNanning University Training Building Power DistribGX Agricultural Engineering Vocational and TechnicPujin Road Phase II Sewage Pipe Box-type SubstatioInfrastructureBaise Sports Center Charging Piles Power DistributNapo People's Court Charging Piles Power DistributSmart Park Charging Piles Power Distribution ProjeEnergy and PowerPower Distribution Project of Nanning Rail TransitTian'e-Beihai Highway Power Distribution ProjectGuanyang - Pingle Mechanical & Electrical EngineerTransportation1.92MW Distributed Photovoltaic Power ProjectPhotovoltaic Power Generation Project (Phase I)Agriculture, Forestry, Animal Husbandry & FisheryProjects OverviewNews CenterVideo UpdatesIndustry FAQIndustry White PaperGroup ProfileIndustrial Products Platform QiansimaiHonors and QualificationsSeeking Overseas Distributors
Share to:

SWMNS Low-voltage Draw-out Switchgear Assemblies

SWMNS Low-voltage Draw-out Switchgear Assemblies are modular and multifunctional low-voltage distribution cabinets. They are applied to low-voltage systems in all high-reliability scenarios in fields such as metallurgy, petroleum, chemical industry, industrial and mining enterprises, and infrastructure: power distribution and motor control systems. The cabinet structure adopted by SWMNS has a high degree of flexibility.

According to the customer's needs or different usage scenarios, various models and specifications of components can be installed in the cabinet; according to different electrical equipment, multiple types of feeder units can be installed in the same row of cabinets or the same cabinet. For example, feeder circuits and motor control circuits can be mixed and installed together. SWMNS is a full-range low-voltage switchgear that can meet all your needs. It is suitable for all low-voltage systems below 6300A. SWMNS can provide a high level of reliability and safety.
Product Description
Specification

1. Normal use conditions

Applications: power distribution, motor control.

Implementation standards: IEC 60349, GB7251.12-2013.

Ambient temperature: -5℃~40℃.

Ambient relative humidity: not more than 50% at 40℃. At lower temperatures, higher relative humidity is allowed, and condensation may occur occasionally (e.g. 90% at 20℃).

Installation location: indoors.

Altitude: ≤2500m.

If the above conditions cannot be met, the user should inform the manufacturer when placing an order. No frequent severe vibration.

If the use exceeds the normal conditions specified in GB3906, it shall be negotiated between the user and the manufacturer.


2. Structural characteristics

In order to facilitate the installation of equipment and on-site construction, a dedicated cable channel is set up in the distribution cabinet, and corresponding cable fixings are attached.

Each position of the drawer unit is accurately positioned and clearly indicated, and each position can be locked with up to 3 padlocks.

The special profile structure and connection method ensure the strength of the cabinet.

The drawer unit uses contact wires to be directly connected to the "L"-shaped vertical busbar, which is simple and reliable.

The unique three-section guide rail makes the drawer more flexible and convenient to enter and exit, and the internal components and wiring can be inspected, maintained or replaced without removing the drawer unit from the cabinet.


3. Division of areas within the distribution cabinet

According to the different functions of each part, the distribution cabinet can be divided into 4 independent compartments.

Horizontal busbar room (a separate compartment located behind or on top of the cabinet)

When the wiring is connected from the front, the horizontal busbar is placed behind the cabinet.

The horizontal busbar is also placed on the top of the cabinet.

Vertical busbar room (a separate compartment located on the left side of the rear of the cabinet).

The vertical busbar adopts "L"-shaped busbar and is placed in a dedicated fully enclosed functional panel, which not only ensures the stability of the vertical busbar, but also ensures that the protection level of its live parts can reach IP20 after the drawer unit is pulled out.

Functional unit room (each independent compartment located on the left side of the cabinet front) drawer unit or fixed partition unit.

Cable room

When the wiring is front-out, it is located on the right side of the front of the cabinet; when the wiring is rear-out, it is located on the right side of the rear of the cabinet.




Technical Parameters

1.1 Inlet and outlet form: cable/bus duct (bridge)

1.2 Cable entry and exit: top/bottom

1.3 Wiring type: front of cabinet/back of cabinet

1.4 Protection grade: IP30, IP40, IP54

1.5 Functional unit isolation form: full isolation or partial isolation

2 Cabinet size

2.1 Height: 2200

2.2 Width: 600, 800, 900, 1000

2.3 Depth: 600, 800, 1000

2.4 Surface treatment: high voltage electrostatic epoxy powder spraying ≥60 μ

3 Electrical data

3.1 Rated insulation voltage: up to 1000V

3.2 Rated operating voltage: up to 660V

3.3 Rated frequency: 50/60Hz

3.4 Rated impulse withstand voltage: 8kV

3.5 Auxiliary circuit rated voltage: AC380, 220V/DC220V

3.6 Overvoltage level: I

3.7 Pollution degree: 3

3.8 Rated current: 6300A

3.9 Horizontal busbar rated current: 6300A

3.10 Vertical busbar rated current: 2000A, 1000A

4 horizontal busbars

4.1 Rated short-time withstand current: 50/80kA 4.2 Rated peak withstand current: 105/176KA

5 vertical busbars

5.1 Rated short-time withstand current: 50kA 5.2 Rated peak withstand current: 105kA 6 Grounding system: TT, IT, TN-S, TN-C-S 7 Maximum incoming and outgoing circuit breaker: 4000A

The minimum depth of a cabinet with glass doors is 725.

To facilitate the installation of horizontal busbars, the cabinet depths of the same arrangement system should be uniform. If not, a 400mm wide busbar transfer cabinet should be added at each connection.

The depth of the cabinet with busbar bridge or busbar duct inlet and outlet should be 800. For products with special requirements, please consult the manufacturer.